INTRODUCTION

A contestable works program exists under the NSW Electricity Supply Act 1995. This provides electricity customers in NSW with the right to choose suitably qualified and accredited persons to connect their premises to the Network Operator’s distribution network, arrange for the supply of more electricity from the distribution network than they are currently consuming, or to extend the distribution network to reach their premises.

To ensure that the electrical distribution network and connection to the distribution network remains reliable and safe, only Accredited Service Providers (ASPs) operating under the ASP scheme administered by NSW Trade & Investment, may perform this work.

Employees and sub-contractors of ASPs must be suitably qualified and registered with the ASP scheme before seeking authorisation from the local Network Operator to work on or near the electricity network.

ASP LEVELS

The ASP Scheme accredits different types (levels) of work.

LEVEL 1 ACCREDITATION

allows for both overhead and underground construction work on distribution networks which are located adjacent to roadway. Level 1 service providers may be accredited for the following work categories:

  • overhead lines
  • underground lines.

LEVEL 2 ACCREDITATION

allows for construction of service lines between the distribution system and the point of connection to the premises and for the installation and energisation of metering services. Level 2 service providers may be accredited for the following work categories:

  • disconnection and reconnection
  • underground service lines
  • overhead service lines
  • metering and energising new installations
  • installing contestable market metering

LEVEL 3 ACCREDITATION

allows for the design of distribution networks. Service providers may be accredited for the following work categories:

  • overhead lines
  • underground lines.

level 2 qualifications

The services that can be undertaken by a Level 2 ASP are as follows (but not limited to):

Class 2A
(previously known as Category 1) – Disconnect and reconnect.

  • Disconnection and reconnection of service lines at the connection point – but only work at the connection point that does not involve accessing network operator assets and no mechanical changes to network assets are required.

Class 2B
(previously known as Category 2) – Work on underground service conductors. For example:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • installation and connection of underground service lines in accordance with the NSW Service & Installation Rules;
  • relocate/upgrade an existing underground service line and restore supply on completion;
  • disconnection and reconnection of underground service lines at the point of common coupling and the connection point; and
  • replacement of service protection device and meter protection device fuse(s), service active and neutral links

Class 2C
(previously known as Category 3) – Work on overhead service conductors. For example:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • installation and connection of overhead service lines in accordance with the Service & Installation Rules of NSW;
  • relocate/upgrade an existing overhead service line and restore supply on completion;
  • disconnection and reconnection of overhead service lines at the point of common coupling and the connection point; and
  • replacement of service protection device and meter protection device fuse(s), service active and neutral links.

Class 2D
(previously known as Category 4) – Installing metering for meter types 5 to 6 and other Network Operator service equipment:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • installation and removal of whole current metering equipment in accordance with the local distributor’s published standards; and
  • disconnection and reconnection of the installation at the connection point; and
  • energising new installations.

An ASP may only remove or install meters of types 1 to 4 if the ASP is also accredited as a meter provider with the Australian Energy Market Operator (AEMO) or the ASP is undertaking this work as a sub-contractor to another company which is properly accredited by AEMO for this purpose.

Class 2X
Non-electrically qualified. This class allows non-electrically qualified personnel to be registered with the ASP Scheme in accordance with the Scheme Rules. It also allows application to be made to a distributor for authorisations not covered in the Scheme Rules, where the requirements for those authorisations are set by the Distributors. Examples of specific authorisations that may be required by a distributor include:

  • electrical trade related works performed by electrical trades apprentices covered by a training contract that may be required to work on or near the network under direct and constant supervision of an appropriately authorised person,
  • work performed by persons engaged by a telecommunications network operator on telecommunications assets attached to electricity network operator assets,
  • trades assistant work such as safety observer, rescue assistant and plant operator.

Level 2 Training and Assessment requirements


Level 2 ASP Qualification and training requirements
Classes of Contestable Services
(type of work)
ASP Scheme Qualification Criterion for Level 2 ASPs
Training organisations must be registered with Australian Skills Quality Authority or their state training authority and must have the relevant qualification and unit of competency on their scope of registration to deliver training and/or assessment.
Core Qualifications (refer Note 1) Additional Mandatory Competency Units (refer Note 2)
Class 2A _
Disconnect and
reconnect at
connection point
Meet requirements for class 2B or 2C
OR
Curently registered for Disconnect / reconnect
(former Level 2 Category 1)
UETTDREL16 - Working safely near live electrical apparatus
AND
UETTDRRF11 - Testing of connections to low voltage electricity networks
Class 2B _
Underground Services
(previous Category 2)
UEE30811 - Certificate III in Electro-technology
Electrician (or equivalent)
OR
UET30812 - Certificate III in ESI - Power Systems -
Distribution Cable Jointing
UETTDRIS55 - Install and maintain low voltage underground services
AND
UETTDRRF11 - Testing of connections to low voltage electricity networks,
Class 2C _
Overhead Services
(previous Category 3)
UEE30811 - Certificate III in Electrotechnology
Electrician (or equivalent)
OR
UET30612 - Certificate III in ESI - Power Systems -
Distribution Overehad
UETTDRIS56 - Install and maintain low voltage overhead services
AND
UETTDRRF11 - Testing of connections to low voltage electricity networks,
Class 2D _
Metering & Energisind
Installations - including
disconnect and reconnect
(previous Category 4)
UEE30811 - Certificate III in Electro-technology
Electrician (or equivalent)
UETTDREL16 - Working safely near live electrical apparatus
AND UEENEEK142A - Apply enviromentally and suistainable energy procedures in the energy sector
AND either
  1. UETTDRIS60 - Install and replace power system meters and associated equipment, or,
  2. UEENEEG171A - install, setup and commission interval metering
AND
UETTDRRF11 - Testing of connections to low voltage electricity networks
Note 1:
Upon verification; those holidng an equivalent qualification to
  • UET30612 and/or UET30812 documented in the UET12 Training Package and all corresponding units of competency that proceed back to and are inclusive of UTT30101 and/or UTT30301 documented in the UTT98 Training Package will also meet the qualification requirements noted in this Level 2 table; or
  • UEE30811 documented in the UEE11 Training Package and all corresponding units of competency that proceed back to and are inclusive of UTE31199 documented in the UTE99 Training Package will also meet the qualification requirements noted in this Level 2 table.
Note 2:
Registered Training Organisations (RTO's) must ensure that any/all prerequisite units of competency (as specified within each of the relevant competency standards) have been achieved prior to awarding any of the units of competency specified within "Additional Mandatory Competency Units" column of Level 2 table.
Details are to be submitted in the qualifications section of the Level 2 ASP Application Form

Transitional arrangements

(a) All existing Level 2 ASPs and personnel registered before December 31st 2015 will continue to have their training recognised as before and to hold the relevant categories of registration.
(b) From December 31st 2015, any evidence of training which complies with the table above will be accepted as part of an application for registration.
(c) Until 31 December 2015, the scheme administrator will accept training certificates issued under the previous method used to train Level 2 ASPs as part of an application for registration. This will allow RTOs to transition to the new training requirements and allow individuals to complete their training and submit an application in a timely manner.
(d) From 1 January 2016, only training which complies with Appendix B will be accepted as part of an application for registration unless an individual has been registered previously as per (a) above.

CATEGORY 2 UNDERGROUND
TRAINING AND ASSESSMENT

UETTDRIS55
Install and maintain low voltage underground services

Unit Descriptor: This Competency Standard Unit covers the installation, maintenance and connection of low voltage underground service lines and associated equipment (between the connection point and the point of supply - customers’ premises). Maintenance includes the repair and replacement of service cables, service fuses and the replacement and repair of service hardware, the identification and rectification of faults. It also covers insulation, voltage, polarity testing and phase rotation.

Learning Outcomes: At the completion of this Unit of Competency, you should be able to:
1. Prepare for the installation and maintenance of LV underground services and associated equipment
2. Carry out installation and maintenance of LV underground services and associated equipment
3. Complete the installation and maintenance of LV underground services and associated equipment.

Prerequisite Unit(s) Competencies: Granting of competency in this unit shall be made only after competencies in the Common Unit Group have been completed plus all the competencies in one (1) of the identified Pathway Unit Group(s): Transmission Overhead, Distribution Overhead, Rail Traction, Distribution Cable Jointing, Electrotechnology Electrician (Refer to Pathway over).

Scheduling: The delivery duration is approximately 2 days or as required.

CATEGORY 3 OVERHEAD
TRAINING AND ASSESSMENT

UETTDRIS56
Install and maintain low voltage overhead services

This Competency Standard Unit covers the installation, maintenance and connection of low voltage overhead service lines and associated equipment (between the connection point and the point of supply - customers’ premises). Maintenance includes the repair and replacement of service cables, service fuses and the replacement and repair of service hardware, the identification and rectification of faults. It also covers insulation, voltage, polarity testing and phase rotation.

Learning Outcomes: At the completion of this Unit of Competency, you should be able to:
1. Prepare for the installation and maintenance of LV overhead services and associated equipment
2. Carry out installation and maintenance of LV overhead services and associated equipment
3. Complete the installation and maintenance of LV overhead services and associated equipment

Prerequisite Unit(s) Competencies: Granting of competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed. Where pre-requisite pathways have been identified. All competencies in the Common Unit Group must be have been completed plus all the competencies in one (1) of the identified Pathway Unit Group(s): Transmission Overhead, Distribution Overhead, Rail Traction, Distribution Cable Jointing, Electrotechnology Electrician.

Scheduling: The delivery duration is approximately 4 days or as required.

CATEGORY 4 METERING &
ENERGISING INSTALLATIONS
TRAINING AND ASSESSMENT

UETTDRIS60
Install and replace power system energy meters and associated equipment

This Competency Standard Unit covers the installation and replacement of whole current energy meters and associated equipment, where replacement may include the identification of faults in accordance with established procedures and return to service. It includes the requirements to ascertain if normal functions of the meters and associated equipment are in accordance with established procedures.

Learning Outcomes: At the completion of this Unit of Competency, you should be able to:
1. Prepare for the installation and replacement of energy meters and associated equipment
2. Carry out the installation and replacement of energy meters and associated equipment
3. Complete the installation and replacement of energy meters and associated equipment

Prerequisite Unit(s) Competencies: Granting of competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed. Where pre-requisite pathways have been identified. All competencies in the Common Unit Group must be have been completed plus all the competencies in one (1) of the identified Pathway Unit Group(s): Distribution Overhead, Distribution Cable Jointing, Electrotechnology Electrician.

Scheduling: The duration of this unit of competency is approximately 4 days or as required.

Electrotechnology (Electrician’s pathway) Recognition

RTOs are obligated to recognise training and assessing that you have already undertaken, so you don’t need to undertake it again.
* UEENEEG105A Extract states that ‘Those holding an ‘Unrestricted Electrician’s Licence’ or equivalent issued in an Australian State or Territory meet the requirements of this unit and its pre-requisite requirements. A ‘licensed electrician’ applying for an ‘electrical contractors licence’ may be required to undertake this unit to demonstrate their currency with verification of compliance requirements. In this case they are deemed to have met the pre-requisites for this unit provided that they hold a current ‘electricians licence’ or its equivalent issued in an Australian State of Territory and have recently been in permanent employment as a licensed electrician sufficient to evidence current knowledge of applicable standards and regulations’.
Note: Electrician’s must still be subject to the recognition process for this to occur.

  Electrotechnology Electrician Pathway Group
Unit Code Unit Title
UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work
UEENEEG006A Solve problems in single and three phase low voltage machines
UEENEEG033A Solve problems in single and three phase electrical apparatur and circuits
UEENEEG063A Arrange circuits, control and protection for general electrical installations
UEENEEG106A Terminate cables, cords and accessories for low voltage circuits
UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
UEENEEG109A Develop and connect electrical control circuits
UEENEEK142A Apply enviromentally and sustainable energy procedures in the energy sector
UETTDRIS67 Solve problems in energy supply network equipment
  Common Unit Group
Unit Code Unit Title
UEENEEE101A Apply Ocupational Health and Safety regulations, codes and practices in the workplace
UEENEEE102A Fabricate, assemble and dismantle utilities industry cmponents
UEENEEE104A Solve problems in d.c. Circuits
UEENEEE105A Fix and secure electrotechnology equipment
UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications
UEENEEG101A Solve problems in electromagnetic devices and related circuits
UEENEEG102A Solve problems in low voltage a.c. Circuits
UETTDREL16 Working safely near live electrical apparatus
ACCREDITATION AUTHORISATION

To become accredited an applicant must apply in writing, using the
approved application form along with:
1. the completed application form;
2. evidence of the required competencies;
3. the completed form for the registration of persons who will be
seeking to be authorised by the electricity distributor/s to undertake
contestable services;
4. evidence of meeting the insurance requirements; and
5. the application fee Click here for details Department of Planing and Environment
02 82751960
asp.scheme@trade.nsw.gov.au
ASP Scheme PO Box 435 | Parramatta | NSW 2124

Following registration, an ASP must seek to have those personnel
authorised by the local electricity distributor. Only personnel who are
currently registered with the Scheme can be authorised.

The local electricity distributor is responsible for determining who is
authorised to work on or near the distribution network. The electricity
distributor/s will require registered personnel to undertake training in
relevant safety and operating procedures and be familiar with and show
they can comply with their respective safety management systems,
electrical safety rules and other relevant policies.

The 3 NSW Local Electricity Distributors are detailed below:



Statutory Training also required

Everybody who works on or near the Electricity Supply Network must be deemed competent in the tasks they are to perform; and trained and assessed yearly in the appropriate escape, release and rescue procedures for those tasks.

ASP Annual Refresher Training

Level 2 ASPs Civil

* for cable jointing work from an EWP no poles > 2m above ground level and from EWPs

+ for live cable jointing work in a trench enviroment

Unit of Competency Class 2D Class 2B Class 2C Class 2X
HLTAID001
Provide Cardio Pulmonary Resuscitation
UETTDRRF02B
Perform pole top rescue
UETTDRRF03B
Perform EWP rescue
UETTDRRF06B
Perform rescue from a live LV panel
UETTDRRF08B
Perform EWP controlled descent escape
UETTDRRF10B
Provide first aid in an ESI enviroment
UETTDRRF11
Testing of connections to low voltage electricity networks
www.iacsafetyservices.com.au or

Important: Statutory Training is not included in the specific Category Accreditation training and must be undertaken separately.
This is due to the fact, that many students will have already undertaken these studies especially if they are current ASPs upgrading their accreditations; each students will have different requirements associated with their accreditation; finally and perhaps more importantly, the ASP initial training and assessment study schedule is intensive and time restrictions and workloads simply would not allow for this training to happen in the time frames allocated.

VENUES

Blacktown
Unit 1 / 39-41 Fourth Ave Blacktown NSW 2148

Thornton
Lot 8 / 13 Hartley Drive Thornton NSW 2322 (Near Newcastle)

TIME

07:30
to 15:30
every day.

Note: THese times are
subjected to vary.

Students
please note:
Classes start
ON TIME

07:45

Onward
No Student
Admittance.
No Exception.

DURATION

Class Schedule
Monday Tuesday Wednesday Thursday Friday
Metering Blacktown Blacktown
Overhead Blacktown Thornton Thornton
Underground Blacktown Thornton
Pre-requisites Practicals Thornton
Rescues Blacktown Thornton
Essential ESR Thornton Blacktown

UETTDRIS60 Install and replace power system energy meters and associated equipment [Metering(Category IV / 2D)]
UETTDRIS56 Install and maintain low voltage overhead services [Overhead (Category III / 2C)]
UETTDRIS55 Install and maintain low voltage underground services [Underground (Category II / 2B)]

Summary
Monday and Tuesday = Blacktown
Wednesday and Thursday = Thornton

COSTS

Disconnect and reconnect at a connection point (Category I / 2A) must meet requirements for class 2B or 2C.

Please note:
If completing 2C with another category you’ll be required to attend 4 days face to face training. Not 5.
All online training overlaps each category.

If you commit to complete all 3 categories, you will receive a $300 discount and FREE ESI rescue training (Valued at $425).
If you complete 2 of the categories you will receive FREE ESI rescue training (Valued at $425).

Please note that prices are subject to change.

$7000
Save $300

$5,200

$4,800

$4,500

The Units above are those which typically are outstanding (not already achieved
under UEENEEG105A recognition), from both the common and
Electrotechnology Electrical pathways.

APPLY to study Student Guide

Details required to enroll

Company Student Training
Name First name Course date / Venue
Postal address Last name
Phone Address
Email Contact number
Email address
Unique Student Identification
number (USI)
www.usi.gov.au
Date of Birth
Copy of electrical license or
any relevant qualifications

THE next step

Apply to study

For further assistance, feel free to talk to one of our friendly staff on
1300 887 317 or email egistrar@iac.edu.au

Version 3, February 2020

Guide to register as an ASP 2a – 2c

For all enquiries, please contact the ASP Scheme on (02) 8275 1960 or email asp.scheme@planning.nsw.gov.au 

Step 1.

You need to fill out the Level 2 application form for accreditation
with the NSW Department of Planning & Environment,
https://energy.nsw.gov.au/media/1421/download or

Click here for application form

Provide a list of all your employees/subcontractors that will be working with you as a level 2 ASP (see table inside document).
Provide evidence of Public and Products Liability insurance (minimum cover of $10M).
Ensure “Electricity Distributors of NSW” are noted as interested parties on the Public and Products Liability insurance policy.

Step 2.

Please note this can be completed at ANY TIME.
Please contact your Electrical Supply Distribution Network (ESDN) you plan to work for Ausgrid / Endeavour Energy / Essential Energy.
As you’ll need to complete their Initial Electrical Safety rules. Please note each ESDN have a different process with this. Please contact them regarding this process.

Ausgrid: 8745 1561 or 4951 0853 Email: training@ausgrid.com.au
Endeavour Energy: 98536946 or 98535043 Email: authorisations@endeavourenergy.com.au
Essential Energy: 6643 7850 Email: authorisations@essentialenergy.com.au

Step 3.

Complete your application / induction with your ESDN. This process will vary between each ESDN

Step 4.

Once you’ve obtained your ASP accreditation number and your authorisation card from your ESDN you can start to perform level 2 ASP work

Guide to register as an ASP 2d ONLY

Please contact IAC Safety Services

registrar@iac.edu.au

The Process to Work as an ASP

If you want to work as an ASP (Accredited Service Provider) in the NSW energy distribution network, you need to follow a few steps. One major step you must undertake is ASP Pathways Level 2 training. The extent of training you complete determines the types of roles you can perform in the electrical services industry. For example, an ASP 1 can only perform restricted electrical service work. Here are the steps to get on a Level 2 ASP list.

Choose the work you want to do: You can choose the level of ASP work that you want to do, and this informs the types of training and mandatory units you’ll need to complete. We’ve listed the training requirements for each level and category below.

Undertake training:  Complete the core units and mandatory units required to perform electrical work aligned with your desired role.

Apply for accreditation:  Once your training is complete, you must gather your paperwork and apply in writing for accreditation to the NSW Dept of Planning and Environment. This registers you as an ASP.

Apply for authorisation:  Finally, seek authorisation from your ESDN (Electrical Supply Distribution Network) such as Ausgrid, Endeavour Energy or Essential Energy. You’ll then be authorised to perform the duties aligned with your level of training.

Who can benefit from ASP Pathways Level 2?

Anybody who wants to work as an Accredited Service Provider (ASP) should consider our ASP pathways Level 2 training.

The ASP Level 2 Qualifications

The services that can be undertaken by a Level 2 ASP are as follows (but not limited to):

Class 2A – Disconnect & Reconnect:

  • Disconnection and reconnection of service lines at the connection point – but only work at the connection point that does not involve accessing network operator assets and no mechanical changes to network assets are required.

Class 2B – Work on underground service conductors including:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures; 
  • installation and connection of underground service lines in accordance with the NSW Service & Installation Rules; 
  • relocate/upgrade an existing underground service line and restore supply on completion; 
  • disconnection and reconnection of underground service lines at the point of common coupling and the connection point; and
  • replacement of a service protection device (including where it includes a meter protection device) and service active and neutral links. 

Class 2C – Work on overhead service conductors including:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures; 
  • installation and connection of overhead service lines in accordance with the Service & Installation Rules of NSW; 
  • relocate/upgrade an existing overhead service line and restore supply on completion; 
  • disconnection and reconnection of overhead service lines at the point of common coupling and the connection point; and
  • replacement of a service protection device (including where it includes a meter protection device) and service active and neutral links.

Class 2D – Energising network operator service equipment including service protection devices/fuses:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • disconnection and reconnection of the service equipment (including service protection devices/fuses) at the connection point;
  • installation, replacement and removal of service protection devices/fuses as required by distributors in accordance with the NSW Service and Installation Rules 
  • energising service equipment including service protection devices/fuses.

In relation to a basic meter (as defined in Schedule 6 of the Electricity Supply Act 1995) request received by the distributor prior to 1 December 2017, the installation and removal of the whole current metering equipment in accordance with the local distributor’s published standards to the extent that such installation or removal relates to a basic meter. An ASP may only remove or install meters if the ASP is accredited as a meter provider with the Australian Energy Market Operator (AEMO) or the ASP is undertaking this work as a subcontractor to another company that is properly accredited by AEMO for this purpose.

New to Industry Units

Listed below are the units you’ll need to achieve regarding of what category you achieve to be accredited with the ASP Scheme. These units might vary from each Electrical Supply Distribution Network owner.

Yearly Refresher Units 

  • HLTAID009, Provide cardiopulmonary resuscitation 
  • UETDREL006, Work safely in the vicinity of live electrical apparatus as a non-electrical worker 
  • UETDRMP001 –  ESI safety rules for work on, near or in the vicinity of electrical apparatus 
  • UETDRMP004 – Perform elevated work platform controlled descent escape* 
  • UETDRMP005 – Perform EWP rescue* 
  • UETDRMP006 – Perform pole top rescue* 
  • UETDRMP007 – Perform rescue from live LV panel 
  • UETDRMP010 – Provide first aid in an ESI environment 
  • UETDRMP011 – Testing of connections to low voltage electricity networks 

Stand-alone units 

  • UEERE0001 – Apply environmentally and sustainable procedures in the energy sector^ 
  • UETDREL001 – Apply environmental requirements 
  • UETDREL004 – Operate plant and equipment in the vicinity of live electrical apparatus* 
  • UETDREL005 – Work safely in the  vicinity of live electrical apparatus

*only required for Overhead

^only required for Metering

 

Class 2A (Disconnect & Reconnect)

With Class 2A qualification you’re able to perform all the duties prescribed by the lower levels, but you can also disconnect and reconnect services at the connection source. It’s important to note that this does not include accessing network operator assets or making any changes to network assets.

Core requirements:
Core units: Meet qualifications for class 2B and 2C or currently be registered for Disconnect/Reconnect

Units of Competency achieved:
UETDREL005 – Work safely in the vicinity of live electrical apparatus; and
UETDRMP011 – Testing of connections to low voltage electricity networks

Class 2B (Underground)

With Class 2B accreditation you can perform all the duties applicable to Class 2C and 2D, but you can also work on underground service conductors.

Core requirements:
Qualifications you must hold: Electrical Contractors Licence – UEE30820 – Certificate III in Electro-technology Electrician or UET30821 – Certificate III in ESI – Distribution Underground

Units of Competency achieved:
UETDREL001 – Apply environmental requirements
UETDREL005 – Work safely in the vicinity of live electrical apparatus; and
UETDRMP011 – Testing of connections to low voltage electricity networks; and
UETDRIS011 – Install and maintain low voltage underground services

Class 2C (Overhead)

With Class 2C, you can perform all duties allowed with Class 2D, but you can also work on overhead service conductors.

Core requirements:
Qualifications you must hold:
Electrical Contractors Licence – UEE30820- – Certificate III in Electro-technology Electrician or UET30621 – Certificate III in ESI – Distribution Overhead

Units of Competency achieved:
UETDREL001 – Apply environmental requirements
UETDREL004 – Operate plant and equipment in the vicinity of live electrical apparatus
UETDREL005 – Work safely in the vicinity of live electrical apparatus; and
UETDRMP011 – Testing of connections to low voltage electricity networks: and
UETDRIS010 – Install and maintain low voltage overhead services

Class 2D (Metering)

Class 2D certification allows you to perform a range of tasks, including installing metering for Type 5 and 6 meter types and disconnection and reconnection of whole current metering equipment.

Training requirements:
Core units: UEE30820 – Certificate III in Electro-technology Electrician

Units of Competency achieved:
UEERE0001 – Apply environmentally and sustainable procedures in the energy sector
UETDREL001 – Apply environmental requirements
UETDREL005 – Work safely in the vicinity of live electrical apparatus; and
UETDRMP011 – Testing of connections to low voltage electricity networks
UETDRIS014 – Install and replace energy meters and associated equipment; or
UEEEL0013 – Install, setup and commission interval metering.

2025 Upcoming Dates

January

13

Blacktown

New ESI Level 2

14

Blacktown

New ESI Level 2

15

Blacktown

Metering Level 2

16

Blacktown

Metering Level 2

20

Thornton

Overhead & Underground UETDRIS010/011

21

Thornton

Overhead & Underground UETDRIS010/011

22

Thornton

Overhead & Underground UETDRIS010/011

23

Thornton

Overhead & Underground UETDRIS010/011

February

17

Blacktown

New ESI Level 2

18

Blacktown

New ESI Level 2

19

Blacktown

Metering Level 2

20

Blacktown

Metering Level 2

24

Thornton

Overhead & Underground UETDRIS010/011

25

Thornton

Overhead & Underground UETDRIS010/011

26

Thornton

Overhead & Underground UETDRIS010/011

27

Thornton

Overhead & Underground UETDRIS010/011

March

3

Blacktown

New ESI Level 2

4

Blacktown

New ESI Level 2

5

Blacktown

Metering Level 2

6

Blacktown

Metering Level 2

10

Thornton

Overhead & Underground UETDRIS010/011

11

Thornton

Overhead & Underground UETDRIS010/011

12

Thornton

Overhead & Underground UETDRIS010/011

13

Thornton

Overhead & Underground UETDRIS010/011

31

Blacktown

New ESI Level 2

April

1

Blacktown

New ESI Level 2

2

Blacktown

Metering Level 2

3

Blacktown

Metering Level 2

7

Thornton

Overhead & Underground UETDRIS010/011

8

Thornton

Overhead & Underground UETDRIS010/011

9

Thornton

Overhead & Underground UETDRIS010/011

10

Thornton

Overhead & Underground UETDRIS010/011

May

5

Blacktown

New ESI Level 2

6

Blacktown

New ESI Level 2

7

Blacktown

Metering Level 2

8

Blacktown

Metering Level 2

12

Thornton

Overhead & Underground UETDRIS010/011

13

Thornton

Overhead & Underground UETDRIS010/011

14

Thornton

Overhead & Underground UETDRIS010/011

15

Thornton

Overhead & Underground UETDRIS010/011

June

16

Blacktown

New ESI Level 2

17

Blacktown

New ESI Level 2

18

Blacktown

Metering Level 2

19

Blacktown

Metering Level 2

23

Thornton

Overhead & Underground UETDRIS010/011

24

Thornton

Overhead & Underground UETDRIS010/011

25

Thornton

Overhead & Underground UETDRIS010/011

26

Thornton

Overhead & Underground UETDRIS010/011

July

7

Blacktown

New ESI Level 2

8

Blacktown

New ESI Level 2

9

Blacktown

Metering Level 2

10

Blacktown

Metering Level 2

14

Thornton

Overhead & Underground UETDRIS010/011

15

Thornton

Overhead & Underground UETDRIS010/011

16

Thornton

Overhead & Underground UETDRIS010/011

17

Thornton

Overhead & Underground UETDRIS010/011

August

4

Blacktown

New ESI Level 2

5

Blacktown

New ESI Level 2

6

Blacktown

Metering Level 2

7

Blacktown

Metering Level 2

11

Thornton

Overhead & Underground UETDRIS010/011

12

Thornton

Overhead & Underground UETDRIS010/011

13

Thornton

Overhead & Underground UETDRIS010/011

14

Thornton

Overhead & Underground UETDRIS010/011

September

1

Blacktown

New ESI Level 2

2

Blacktown

New ESI Level 2

3

Blacktown

Metering Level 2

4

Blacktown

Metering Level 2

8

Thornton

Overhead & Underground UETDRIS010/011

9

Thornton

Overhead & Underground UETDRIS010/011

10

Thornton

Overhead & Underground UETDRIS010/011

11

Thornton

Overhead & Underground UETDRIS010/011

October

13

Blacktown

New ESI Level 2

14

Blacktown

New ESI Level 2

15

Blacktown

Metering Level 2

16

Blacktown

Metering Level 2

20

Thornton

Overhead & Underground UETDRIS010/011

21

Thornton

Overhead & Underground UETDRIS010/011

22

Thornton

Overhead & Underground UETDRIS010/011

23

Thornton

Overhead & Underground UETDRIS010/011

November

3

Blacktown

New ESI Level 2

4

Blacktown

New ESI Level 2

5

Blacktown

Metering Level 2

6

Blacktown

Metering Level 2

10

Thornton

Overhead & Underground UETDRIS010/011

11

Thornton

Overhead & Underground UETDRIS010/011

12

Thornton

Overhead & Underground UETDRIS010/011

13

Thornton

Overhead & Underground UETDRIS010/011

24

Blacktown

New ESI Level 2

25

Blacktown

New ESI Level 2

26

Blacktown

Metering Level 2

27

Blacktown

Metering Level 2

December

1

Thornton

Overhead & Underground UETDRIS010/011

2

Thornton

Overhead & Underground UETDRIS010/011

3

Thornton

Overhead & Underground UETDRIS010/011

4

Thornton

Overhead & Underground UETDRIS010/011

8

Blacktown

New ESI Level 2

9

Blacktown

New ESI Level 2

10

Blacktown

Metering Level 2

11

Blacktown

Metering Level 2

15

Thornton

Overhead & Underground UETDRIS010/011

16

Thornton

Overhead & Underground UETDRIS010/011

17

Thornton

Overhead & Underground UETDRIS010/011

18

Thornton

Overhead & Underground UETDRIS010/011

FAQs

A level 2 electrician, in the context of the ASP scheme and the NSW electricity distribution network, is a person who holds qualifications as an Accredited Service Provider (ASP) Level 2. There are different classes of ASP 2 qualification, and as you can see above, each class level allows for different work types.

A licensed electrician is not automatically an ASP Level 2 electrician, as they may need some specific ASP training to register as an ASP.

Becoming a Level 2 electrician requires the successful completion of an ASP Level 2 training course. You’ll find all of the details above regarding course prerequisites and the type of training required. Without Level 2 electrical courses, workers aren’t able to register with the ASP scheme as a Level 2 electrician.

The simple steps to become a level 2 electrician are:

  • Complete Level 2 ASP training with IAC Safety Services
  • Apply for accreditation with the ASP Scheme
  • Apply for authorisation from your ESDN

It’s important to remember that ASP Level 2 electricians must complete annual ASP refresher training in order to maintain their registration.

How long your ASP Level 2 Pathways course runs is dependent on how many units you’re required to complete. To complete all of the required units, you’re looking at a commitment of approximately 13 days. Some units are run separately or at different locations, so fast-tracking this course isn’t always possible.

You can only speed up a level 2 electrician course by already completing certain units. In this case, you may be eligible for prior learning, which can potentially reduce your time investment.

You can, however you do still need to be registered as an Accredited Service Provider (ASP). You can work in the network as a Level 1 ASP, too. This simply means you’ve completed ASP Level 1 training instead of ASP Level 2 training courses.

Most workers in the NSW distribution network have completed ASP 1 or 2 training, depending on the role they perform. That said, people with non-electrical backgrounds who perform other roles in the network don’t necessarily need to complete an ASP training course, but must be registered as a non-electrical ASP Class 1X.

The first step is to complete your relevant training through IAC Safety Services. Once you’ve successfully completed the course, you must apply for accreditation with the NSW Dept of Planning and Environment. This step registers you with the ASP Scheme as a Level 2 electrician.

The paperwork doesn’t quite end there, though. Even after registering with the ASP scheme, you still need to become authorised by your ESDN (Electrical Supply Distribution Network). As a Level 2 ASP in NSW, your ESDN is the company you intend to work for. Your possible employers in the NSW distribution network are Endeavour Energy, Ausgrid and Essential Energy.

Once authorised by your ESDN, you’ll be able to perform all the duties aligned with your level of training.

A Level 2 ASP list is basically a registry of electricians and electrical contractors who are qualified and authorised to provide contestable services within the Electricity Supply and Distribution Network (ESDN). Professionals on this list can perform roles such as connecting or disconnecting customers to the network as well as other metering and repair tasks. ASP Level 2 electricians are qualified to perform complex tasks, ensuring that homes and businesses receive a safe and reliable supply of power. The list of Level 2 electricians in NSW ensures only qualified professionals work on the state’s electricity infrastructure.

To become a Level 2 Accredited Service Provider (ASP) in NSW, an electrician must first hold an unrestricted electrical license. In addition, they must complete relevant training courses to become an ASP Level 2. This training gives people the skills to perform jobs such as disconnections, reconnections, and metering. A level 2 service provider must satisfy both the ASP scheme and the relevant electricity distributor that they have the training and credentials to perform the job. Completing ASP pathways, like those offered at IAC Safety Services, ensures you get the necessary accreditation to kickstart your career.

No, holding just a disconnect/reconnect licence does not qualify you to work as an ASP Level 2 electrician. ASP Level 2 accreditation covers more advanced work, such as overhead and underground service lines, metering, and high-risk disconnection or reconnection tasks. Think of it like specialist training for the electrical supply industry. While a disconnect/reconnect licence allows for basic electrical work in your usual occupation, you can only become a qualified Level 2 electrician by completing the appropriate electrical and safety training.

Yes, ASP electricians are required to undertake low voltage rescue (LVR) training. Working in the electrical supply industry involves high-risk environments, and low voltage rescue training gives ASP electricians the skills needed to act quickly and safely in an electrical emergency, such as rescuing colleagues from live low-voltage panels. This training is essential for ensuring all workers are safe and can go home at the end of a day’s work. In Australia, workplace safety is mandatory, and particularly in high-risk settings such as the electrical supply industry. From initial ASP Pathway training to annual refresher courses, LV rescue training is all part of your accreditation.

Before pursuing ASP Level 2 training, aspiring electricians should complete a Certificate III in Electrotechnology, which provides the foundational skills and qualifications required for electrical work in Australia. This course is apprenticeship-based, combining theoretical knowledge with hands-on experience. After obtaining this qualification and gaining practical experience, an electrician can then enrol in specialised ASP Level 2 training, which you’ll need if you want to work for any of the electrical distributors in NSW. Electrician courses are a great way to open the door to new career opportunities.

Apply to Study

    Date of Birth: *

    Category: * 2A2B2C2D

    Upload Student's Electrical Qualifications